TM 9-2320-328-13&P-2
0240-2
DRAFT
0240
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
2.
Remove two locknuts (4), washers (5), screws (6), and blackout relay (7) from cab power distribution box (8).
Discard locknuts.
NOTE
Tag and mark wires prior to removal to ensure proper installation.
3.
Remove two screws (9), wire 1138J (10), and wire 2839J (11) from blackout relay (7).
4.
Disconnect wire 1640M (12) and wire H835M (13) from blackout relay (7).
END OF TASK
INSTALLATION
NOTE
Both blackout relays are installed the same way.
Driver side shown.
1.
Connect wire H835 M (13) and wire 1640M (12) on blackout relay (7).
2.
Install wire 2839J (11) and wire 1138J (10) on blackout relay (7) with two screws (9).
3.
Install blackout relay (7) on cab power distribution box (8) with two screws (6), washers (5), and locknuts (4).
HWT1619