TM-9-2320-328-13-P-2

HEMTT-BASED WATER TENDER (HEWATT)

TECHNICAL MANUAL; OPERATOR’S AND FIELD LEVEL MAINTENANCE MANUAL (INCLUDING REPAIR PARTS AND SPECIAL TOOLS LIST); PART 2 OF 3

MARCH 2009

  TM-9-2320-328-13-P-2 - Page 852 of 1390

TM 9-2320-328-13&P-2
0241-2
DRAFT
0241
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
NOTE
Tag and mark wires prior to removal to ensure proper installation.
2.
Remove nut (3), lockwasher (4), and wire 1640 (5) from negative block terminal (6).
Discard lockwasher.
3.
Remove nut (7), lockwasher (8), and five wires 1138 (9) from positive block terminal (10).
Discard lockwasher.
4.
Remove nut (11), lockwasher (12), and wire (13) from negative block terminal (6).
Discard lockwasher.
5.
Remove nut (14), lockwasher (15), and wire (16) from positive block terminal (10).
Discard lockwasher.
6.
Remove two screws (17), locknuts (18), and negative block terminal (6) from pump house control box (19).
Discard locknuts.
7.
Remove two screws (20), locknuts (21), and positive block terminal (10) from pump house control box (19).
Discard locknuts.
END OF TASK
HWT1590
HWT1591


Back to Top