TM-9-2320-328-13-P-2

HEMTT-BASED WATER TENDER (HEWATT)

TECHNICAL MANUAL; OPERATOR’S AND FIELD LEVEL MAINTENANCE MANUAL (INCLUDING REPAIR PARTS AND SPECIAL TOOLS LIST); PART 2 OF 3

MARCH 2009

  TM-9-2320-328-13-P-2 - Page 877 of 1390

TM 9-2320-328-13&P-2
0248-1
DRAFT
0248
FIELD LEVEL MAINTENANCE
ELECTRICALLY-OPERATED BALL VALVE ELECTRIC MOTOR AND DRIVE ASSEMBLY REPLACEMENT
INITIAL SETUP:
REMOVAL
NOTE
All five electrically-operated ball valve electric motors and drive assemblies are removed
the same way.
Passenger side shown.
1.
Disconnect electric motor connector (1) from valve motor control wire harness connector (2).
NOTE
Electric motor and drive assembly are removed as an assembly.
Note position of electric motor and drive housing on valve prior to removal to ensure
proper installation.
2.
Remove four screws (3) and drive housing (4) from valve (5).
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
HWT1247
Tools and Special Tools
Tool Kit, General Mechanic’s: Automotive
(WP 0398, Item 17)
Materials/Parts
Adhesive, Thread, Locking (WP 0400, Item 6)
Oil, Lubricating (WP 0400, Fig. Item 14)
Preformed Packing (1)
Preformed Packing (1)
References
WP 0391, Fig. 65
Equipment Conditions
Pump house panel G removed (WP 0339)