TM-9-2320-328-13-P-2

HEMTT-BASED WATER TENDER (HEWATT)

TECHNICAL MANUAL; OPERATOR’S AND FIELD LEVEL MAINTENANCE MANUAL (INCLUDING REPAIR PARTS AND SPECIAL TOOLS LIST); PART 2 OF 3

MARCH 2009

  TM-9-2320-328-13-P-2 - Page 879 of 1390

TM 9-2320-328-13&P-2
0248-3/(4 blank)
DRAFT
0248
2.
Install gear (13) on shaft (14) with setscrew (12).
3.
Lightly lubricate preformed packing (11) with clean oil, and install preformed packing (11) and adapter (10) on
electric motor (8) with four screws (9).
4.
Lightly lubricate preformed packing (7) with clean oil, and install electric motor (8) and preformed packing (7)
on drive housing (4) with four screws (6).
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
NOTE
Electric motor and drive assembly are installed as an assembly.
Install electric motor and drive housing on valve as noted prior to removal.
5.
Install drive housing (4) on valve (5) with four screws (3).
6.
Connect electric motor connector (1) on valve motor control wire harness connector (2).
END OF TASK
FOLLOW-ON MAINTENANCE
Install pump house panel G (WP 0339)
END OF TASK
END OF WORK PACKAGE