TM 9-2320-328-13&P-2
0257-4
DRAFT
0257
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
8.
Remove two screws (12) and pump operator’s panel headset jack connector (13) from pump operator’s
panel (14).
END OF TASK
INSTALLATION
NOTE
•
Route intercom cables as noted prior to removal.
•
Install cable ties, split loom, and cushion clips as noted prior to removal.
•
Perform Step (1) through (4) if pump operator’s panel headset jack and pump operator’s
panel intercom cable needs to be installed.
1.
Install pump operator’s panel headset jack connector (13) on pump operator’s panel (14) with two
screws (12).
HWT2014A