PUMP HOUSE PANEL A REMOVAL
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
1.
Remove four screws (1), cover (2), gasket (3), and receptacle (4) from pump house panel A (5).
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
2.
Remove nut (6), lockwasher (7), two washers (8), and screw (9) from pump house panel A (5) and
bracket (10).
Discard lockwasher.
3.
Remove four screws (11), lockwasher (12), and washer (13) from pump house panel A (5) and panel D (14).
Discard lockwasher.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.