TM 9-2320-361-20
14-16. SLAVE RECEPTACLE REPLACEMENT
This task covers:
a. Removal
b. Installation
INITIAL SETUP:
APPLICABLE MODELS
All
MATERIALS/PARTS
Six lockwashers
Locknut
REFERENCES (TM)
TM 9-2320-361-10
TM 9-2320-361-20P
EQUIPMENT CONDITION
Parking brake set (TM 9-2320-361-10).
Battery ground cable disconnected (para. 4-48).
GENERAL SAFETY INSTRUCTIONS
Battery ground cables must be disconnected before
removing slave receptacle.
WARNIN G
Do not remove slave receptacle before disconnecting battery ground
cables. If energized battery cables contact cab, a direct short will
result and may cause injury to personnel.
1. Remove locknut (10), screw (13), ground cable (3), and two lockwashers (12) from rear battery box
support hanger (11). Discard lockwashers (12) and locknut (10).
2. Remove nut (9), screw (5), and positive cables (6) and (8) from positive battery terminal (7).
3. Remove four nuts (18), lockwashers (19), and screws (20) from slave receptacle (1). Discard
lockwashers (19).
4. Remove two screws (4), clamps (2), ground cable (3), and positive cable (6) from back cab panel
support (16).
5. Remove two grommets (15) from cab floor (14) and pull receptacle from cab (17).
b. Installation
1. Install slave receptacle (1) through cab (17) and cab floor (14).
2. Install two grommets (15) on ground cable (3) and positive cable (6) and install on cab floor (14).
3. Install slave receptacle (1) on cab (17) with four screws (20), new lockwashers (19), and nuts (18).
4. Install positive cables (6) and (8) on positive battery terminal (7) with screw (5) and nut (9).
5. Install ground cable (3) on rear battery box support hanger (11) with screw (13), two new
lockwashers (12), and new locknut (10).
6. Install ground cable (3) and positive cable (6) on back cab panel support (16) with two clamps (2) and
screws (4).
14-24