TM 9-2320-361-20
12-59. SAFETY SWITCH FUSE REPLACEMENT
This task covers:
a. Removal
b. Installation
INITIAL SETUP:
APPLICABLE MODELS
REFERENCES (TM)
M185A3, M109A3
TM 9-2320-361-10
MATERIALS/PARTS
Two 250V fuses
TM 9-2320-361-20P
EQUIPMENT CONDITION
l Parking brake set (TM 9-2320-361-10).
l Battery
ground cable disconnected (para. 4-48).
1. Pull safety switch box handle (2) down to OFF position and open cover (4).
2. Remove two 250V fuses (3) from safety switch box (l). Discard fuses (3).
1. Install two new 250V fuses (3) in safety switch box (l).
2. Close cover (4) and push safety switch box handle (2) up to ON position.
FOLLOW-ON TASK: Connect battery ground cable (para. 4-48).
12-96