TM 9-2320-361-34
7-2. 60
AMPERE ALTERNATOR REPAIR (Contd)
15. Remove tiedown strap (1) from three leads (2). Discard tiedown strap (1).
16. Disconnect lead (20) from output plate stud (6).
17. Remove insulating compound from four rectifier terminals (10) and three rectifier terminals (16).
CAUTION
Use heat sink when resoldering leads. Failure to do so may result
in damage
18. Desolder and disconnect six positive rectifier leads (11) from four positive rectifier terminals (10).
19. Remove three screws (12), washers (13), nylon washers (14), positive rectifier plate (9), and positive
rectifier insulator (8) from end housing (3).
CAUTION
Use heat sink when desoldering leads. Failure to do so may result
in damage to equipment.
20. Desolder and disconnect three negative rectifier leads (15) from three negative rectifier terminals (16).
21. Remove two screws (17), washers (18), and negative rectifier plate (19) from end housing (3).
22. Remove four screws (4), output plate (5), O-ring (7), six positive rectifier leads (11), three negative
rectifier leads (15), and leads (2) from end housing (3). Discard O-ring (7).
23. Scribe locating marks (24) on intermediate housing (23), stator (22), and drive end housing (21).
7-6