TM-9-2320-361-34

2-1/2-TON, 6x6, M44A2 SERIES TRUCKS (MULTIFUEL)

TECHNICAL MANUAL; DIRECT SUPPORT AND GENERAL SUPPORT MAINTENANCE

MAY 1992

  TM-9-2320-361-34 - Page 165 of 764

TM 9-2320-361-34
7-2. 60
AMPERE ALTERNATOR REPAIR (Contd)
16. Install new O-ring (4), three negative rectifier leads (13), six positive rectifier leads (9), three
leads (20), and output plate (2) into end housing (5) with four screws (1).
17. Apply silicone compound to negative rectifier plate (17).
18. Install negative rectifier plate (17) on end housing (5) with two washers
(16)
and screws (15).
CAUTION
Do not overheat
rectifier leads when soldering
to
rectifier
terminals. Damage to rectifiers may result.
Use heat sink when soldering. Failure to do so may result in
damage to equipment.
19. Connect and solder three negative rectifier leads (13) to three negative rectifier terminals (14).
20. Apply silicone compound to insulator (6) and positive rectifier plate (7).
21. Install insulator (6) and positive rectifier plate (7) on end housing (5) with three nylon washers (12),
washers (11), and screws (10).
CAUTION
Do not overheat rectifier leads when soldering to rectifier
terminals. Damage to rectifiers may result.
Use heat sink when soldering. Failure to do so may result in
damage to equipment.
22. Connect and solder six positive rectifier leads (9) to four positive rectifier terminals (8).
23. Apply insulating compound to three rectifier terminals (14) and four rectifier terminals (8).
24. Connect lead (18) to output plate stud (3).
25. Install new tiedown strap (19) to four leads (20).
7-14


Back to Top