TM 9-2320-361-34
7-2. 60 AMPERE ALTERNATOR REPAlR(Contd)
CAUTION
●
Do not overheat stator leads when soldering to stator terminals.
Damage to stator may result.
●
Use heat sink when soldering. Failure to do so may result in
damage to equipment.
35. Connect and solder stator leads (1), (2), and (3) to stator terminals (4), (5), and (6).
36. Seal leads (1), (2), and (3) to terminals (4), (5), and (6) with adhesive sealant.
37. Install output plate cover (13) on end housing (12) with two new screw-assembled lockwashers (14).
38. Install new O-ring (11) on end housing (12).
39. Connect three leads (7) to three terminals (8) on regulator (9).
40. Install end cover (10) on end housing (12) with six screws (16).
41. Install access plug (15) on end housing (12). Tighten access plug (15) 24-36 lb-in. (3-4 N.m).
FOLLOW-ON TASKS: . Install alternator (TM 9-2320-361-20).
. Adjust alternator (TM 9-2320-361-20).
7-18