TM 9-2320-361-34
15-40. VERTICAL LEVELING WORM GEAR MAINTENANCE (Contd)
1.
2.
3.
4.
5.
6.
7.
8.
NOTE
●
Install
all
shims
to previously recorded thickness.
●
When
installing
worm gear, check that gear is centered and teeth
mesh with worm wheel. If misalined, remove worm gear and
adjust backlash by removing or adding shims.
Install new shims (20) and worm gear housing (18) on intermediate case mounting studs (22) with
four nuts (17).
Install new shims (19), two washers (23), and screws (24) on worm gear housing (18) and
intermediate case (25).
Install new shims (1) and (11) and bracket (6) on power leveler (21) and shaft (16) with two new
lockwashers (10) and screws (8) and (9).
Install two washers (12), new lockwashers (13), and screws (14) on bracket (6).
Install new safety wire (5) on nuts (17).
Install sprockets (2) on bracket (6) and tighten nut (7).
Install new woodruff key (15) and sprocket (3) on shaft (16) and tighten setscrew (4).
Install new safety wire (5) on sprocket (3).
15-156