TM-9-2320-362-14-P

TRUCK UTILITY: S250 SHELTER CARRIER, 4X4, M1037 FOR TRAFFIC JAM AN/TLQ-17A(V)3 (HMMWV)

TECHNICAL MANUAL; OPERATOR, UNIT, DIRECT SUPPORT AND GENERAL SUPPORT MAINTENANCE MANUAL INCLUDING REPAIR PARTS AND SPECIAL TOOLS LIST FOR ELECTRICAL ENVIRONMENTAL SYSTEM (EES)

APRIL 1992

  TM-9-2320-362-14-P - Page 110 of 353

TM 9-2320-362-14&P
3-32.
INCANDESCENT LAMP AND LENS REPLACEMENT
This task covers:
a. Removal b. Installation
INITIAL SETUP:
Equipment Condition
Circuit breaker is off
1.
Remove lens (4) and O-ring (3) from power interface box (l).
2.
Separate lens (4) from incandescent lamp (2).
1.
Install incandescent lamp (2) into lens (4).
Install lens (4) and O-ring (3) on power interface box (l).
2.
FOLLOW-ON TASK: Turn on circuit breaker.
3-33. 200
AMP ALTERNATOR REPLACEMENT
NOTE
Refer to TM 9-2320-280-20 for replacement of
the 200 amp alternator.
3-80