TEST OPTIONS
POSSIBLE PROBLEMS
Nothing.
1.
WARNING
Read WARNING
on following page.
TEST OPTIONS
Voltage Test or
STE/ICE-R Test #89
REASON FOR QUESTION
This question eliminates
possible problems and
determines where
troubleshooting continues.
YES
NO
Go to step 2 of this fault.
Go to step 5 of this fault.
INITIAL SETUP
Equipment Conditions
Engine shut down (TM 9-2320-365-10)
Materials/Parts
Ties, Cable, Plastic (Item 76, Appendix D)
Tools/Special Tools
Multimeter, Digital (Item 22, Appendix C)
Tool Kit, Genl Mech (Item 44, Appendix C)
Personnel Required
(2)
2-1978
Change 2
u1. NO POWER TO DIGITIZATION RACK
START
Circuit breaker CB11 tripped.
Faulty circuit breaker CB11.
Faulty power cable from
terminal lug TL24 to terminal
lug TL20.
Faulty power cable from
terminal lug TL23 to terminal
lug TL16.
Faulty power cable from
terminal lug TL18 to terminal
block TB2.
Faulty Power Distribution Panel
(PD1).
Is 24 VDC present at
terminal lug TL16?