TM-9-2320-365-20-2

M1078 SERIES, 2 1/2-TON, 4 X 4, LIGHT MEDIUM TACTICAL VEHICLES (LMTV)

TECHNICAL MANUAL; MAINTENANCE INSTRUCTIONS; UNIT MAINTENANCE; VOLUME NO. 2 OF 5

FEBRUARY 2006
CHANGE 3

  TM-9-2320-365-20-2 - Page 1074 of 1432

TEST OPTIONS
REASON FOR QUESTION
YES
NO
TEST OPTIONS
Voltage Test or
STE/ICE-R Test #89
WARNING
Read WARNING
on following page.
4.
u1. NO POWER TO DIGITIZATION RACK (CONT)
2-1984
Change 2
TM 9-2320-365-20-2
Circuit breaker CB11 not
tripped.
Power cable from terminal lug
TL24 to terminal lug TL20 OK.
POSSIBLE PROBLEMS
Faulty circuit breaker CB11.
Faulty power cable from
terminal lug TL23 to terminal
lug TL16.
Is 24 VDC present at
terminal lug TL23?
If 24 VDC is not present,
circuit breaker CB11 is faulty.
If 24 VDC is present, power
cable from terminal lug TL23
to terminal lug TL16 is faulty.
Replace power cable from terminal
TL23 to terminal TL16 (para 20-88).
Replace circuit breaker CB11
(para 20-88).