1.
WARNING
Read WARNING
on following page.
TEST OPTIONS
Voltage Test or
STE/ICE-R Test #89
YES
NO
TEST OPTIONS
REASON FOR QUESTION
INITIAL SETUP
Equipment Conditions
Engine shut down (TM 9-2320-365-10)
Materials/Parts
Ties, Cable, Plastic (Item 76, Appendix D)
Tools/Special Tools
Multimeter, Digital (Item 22, Appendix C)
Tool Kit, Genl Mech (Item 44, Appendix C)
Personnel Required
(2)
u2. NO POWER TO MOBILE TRACKING SYSTEM (MTS) SENSE
2-1988
Change 2
START
Circuit breaker CB1 is not
tripped.
Faulty circuit breaker CB1.
Faulty power cable from
terminal lug TL15 to terminal
lug TL22.
Faulty Power Distribution Panel
(PD2).
Faulty Mobile Tracking System
(MTS) Sense.
POSSIBLE PROBLEMS
Contact supervisor, Mobile Tracking System (MTS)
Sense troubleshooting needs to be performed.
Go to step 2 of this fault.
If 24 VDC is not present, go to
step 2 of this fault.
If 24 VDC
is present perform Mobile
Tracking System (MTS) Sense
troubleshooting.
Is 24 VDC present at
terminal lug TL6?
TM 9-2320-365-20-2