TEST OPTIONS
YES
NO
TEST OPTIONS
REASON FOR QUESTION
2.
Continuity Test or
STE/ICE-R Test #91
u3. NO POWER TO ENHANCED POSITION LOCATION REPORTING SYSTEM (EPLRS) (CONT)
Replace circuit breaker CB5
(para 20-87).
2-1996
Change 2
Perform Special Purpose Kit
Troubleshooting task u1. No Power
to Digitization Rack.
POSSIBLE PROBLEMS
Faulty circuit breaker CB5.
Faulty digitization rack power
supply.
Circuit breaker CB5 is not
tripped.
If continuity is not present,
circuit breaker CB5 is faulty.
If continuity is present,
perform Special Purpose Kits
Troubleshooting task u1. No
Power to Digitization Rack.
Is continuity present through
circuit breaker CB5?