1.
WARNING
Read WARNING
on following page.
TEST OPTIONS
Voltage Test or
STE/ICE-R Test #89
YES
NO
REASON FOR QUESTION
Go to step 2 of this fault.
2-1994
Change 2
u3. NO POWER TO ENHANCED POSITION LOCATION REPORTING SYSTEM (EPLRS)
INITIAL SETUP
Equipment Conditions
Engine shut down (TM 9-2320-365-10)
Materials/Parts
Ties, Cable, Plastic (Item 76, Appendix D)
Tools/Special Tools
Multimeter, Digital (Item 22, Appendix C)
Tool Kit, Genl Mech (Item 44, Appendix C)
Personnel Required
(2)
START
TM 9-2320-365-20-2
If 24 VDC is not present, go to
step 2 of this fault.
If 24 VDC
is present, perform Enhanced
Position Location Reporting
System (EPLRS)
troubleshooting.
Contact supervisor, Ehanced Position
Location Reporting System (EPLRS)
troubleshooting needs to be performed.
Is 24 VDC present at
terminal lug TL8?
POSSIBLE PROBLEMS
Faulty circuit breaker CB5.
Faulty digitization rack power
supply.
Faulty Enhanced
Position Location Reporting
System (EPLRS).
TEST OPTIONS
Circuit breaker CB5 is not
tripped.