1.
WARNING
Read WARNING
on following page.
TEST OPTIONS
Voltage Test or
STE/ICE-R Test #89
YES
NO
TEST OPTIONS
REASON FOR QUESTION
Go to step 2 of this fault.
INITIAL SETUP
Equipment Conditions
Engine shut down (TM 9-2320-365-10)
Materials/Parts
Ties, Cable, Plastic (Item 76, Appendix D)
Tools/Special Tools
Multimeter, Digital (Item 22, Appendix C)
Tool Kit, Genl Mech (Item 44, Appendix C)
Personnel Required
(2)
2-1998
Change 2
u4. NO POWER TO PRECISION LIGHTWEIGHT GLOBAL POSITIONING SYSTEM RECEIVER (PLGR)
START
TM 9-2320-365-20-2
Circuit breaker CB7 is not
tripped.
POSSIBLE PROBLEMS
Faulty circuit breaker CB7.
Faulty digitization rack power
supply.
Faulty Precision Lightweight
Global Positioning System
Receiver (PLGR).
Is 24 VDC present at
terminal lug TL9?
Contact supervisor, Precision Lightweight Global
Positioning System Receiver (PLGR) troubleshooting
needs to be performed.
If 24 VDC is not present, go to
step 2 of this fault.
If 24 VDC
is present, perform Precision
Lightweight Global Positioning
System Receiver (PLGR)
troubleshooting.