TEST OPTIONS
YES
NO
REASON FOR QUESTION
2.
Continuity Test or
STE/ICE-R Test #91
TEST OPTIONS
u5. NO POWER TO DRIVER VISUAL ENHANCEMENT (DVE) (CONT)
Replace circuit breaker CB6
(para 20-87).
2-2004
Change 2
Perform Special Purpose Kit
Troubleshooting task u1. No Power
to Digitization Rack.
Is continuity present through
circuit breaker CB6?
TM 9-2320-365-20-2
Faulty circuit breaker CB6.
Faulty digitization rack power
supply.
POSSIBLE PROBLEMS
Circuit breaker CB6 is not
tripped.
If continuity is not present,
circuit breaker CB6 is faulty.
If continuity is present,
perform Special Purpose Kits
Troubleshooting task u1. No
Power to Digitization Rack.