TEST OPTIONS
YES
NO
REASON FOR QUESTION
2.
Continuity Test or
STE/ICE-R Test #91
TEST OPTIONS
2-2012
Change 2
Replace circuit breaker CB10
(para 20-87).
u7. NO POWER TO MOBILE TRACKING SYSTEM (MTS) (CONT)
Is continuity present through
circuit breaker CB10?
Perform Special Purpose Kit
Troubleshooting task u1. No Power
to Digitization Rack.
POSSIBLE PROBLEMS
Faulty circuit breaker CB10.
Faulty digitization rack power
supply.
Circuit breaker CB10 is not
tripped.
If continuity is not present,
circuit breaker CB10 is faulty.
If continuity is present,
perform Special Purpose Kits
Troubleshooting task u1. No
Power to Digitization Rack.
TM 9-2320-365-20-2