TM-9-2320-365-20-2

M1078 SERIES, 2 1/2-TON, 4 X 4, LIGHT MEDIUM TACTICAL VEHICLES (LMTV)

TECHNICAL MANUAL; MAINTENANCE INSTRUCTIONS; UNIT MAINTENANCE; VOLUME NO. 2 OF 5

FEBRUARY 2006
CHANGE 3

  TM-9-2320-365-20-2 - Page 1090 of 1432

TEST OPTIONS
YES
NO
TEST OPTIONS
2.
Continuity Test or
STE/ICE-R Test #91
REASON FOR QUESTION
u4. NO POWER TO PRECISION LIGHTWEIGHT GLOBAL POSITIONING SYSTEM RECEIVER (PLGR)
(CONT)
Replace circuit breaker CB7
(para 20-87).
2-2000
Change 2
Perform Special Purpose Kit
Troubleshooting task u1. No Power
to Digitization Rack.
TM 9-2320-365-20-2
If continuity is not present,
circuit breaker CB7 is faulty.
If continuity is present,
perform Special Purpose Kits
Troubleshooting task u1. No
Power to Digitization Rack.
POSSIBLE PROBLEMS
Faulty circuit breaker CB7.
Faulty digitization rack power
supply.
Circuit breaker CB7 is not
tripped.
Is continuity present
through circuit breaker CB7?


Back to Top