TEST OPTIONS
REASON FOR QUESTION
YES
NO
TEST OPTIONS
5.
Is continuity present from
terminal lug TL18 to a known
good ground?
Continuity Test or
STE/ICE-R Test #91
u1. NO POWER TO DIGITIZATION RACK (CONT)
Replace Power Distribution Panel
(PD1) (para 20-88).
2-1986
Change 2
TM 9-2320-365-20-2
Circuit breaker CB11 not
tripped.
Circuit breaker CB11 OK.
Power cable from terminal lug
TL24 to terminal lug TL20 OK.
Power cable from terminal lug
TL23 to terminal lug TL16 OK.
POSSIBLE PROBLEMS
Faulty power cable from
terminal
lug TL18 to terminal block TB2.
Faulty Power Distribution Panel
(PD1).
If continuity is not present,
power cable from terminal lug
TL18 to terminal board TB2 is
faulty.
If continuity is present,
Power Distribution Panel (PD1)
is faulty.
Replace power cable from terminal lug
TL18 to terminal board TB2 (para 20-88).