TM 9-2320-365-20-2
2-1218
Change 1
e111.
M1079 110 VAC OUTLET J230 DOES NOT OPERATE (CONT)
6.
KNOWN INFO
TEST OPTIONS
Continuity Test or
STE/ICE-R Test
#91
REASON FOR QUESTION
POSSIBLE PROBLEMS
110 VAC outlets J231,
J232, J233, and J234 OK.
110 VAC outlet J235 does
not operate.
Circuit breaker CB9 OK.
Faulty wire 701C.
Faulty wire 702C.
Faulty relay K35.
Is continuity present on wire
701C from circuit breaker
CB9 to K35 relay base
terminal 9?
If continuity is not present,
wire 701C is faulty.
NO
Repair or replace wire 701C
(para 2-40).
YES