TM-9-2320-365-20-2

M1078 SERIES, 2 1/2-TON, 4 X 4, LIGHT MEDIUM TACTICAL VEHICLES (LMTV)

TECHNICAL MANUAL; MAINTENANCE INSTRUCTIONS; UNIT MAINTENANCE; VOLUME NO. 2 OF 5

FEBRUARY 2006
CHANGE 3

  TM-9-2320-365-20-2 - Page 162 of 1432

TM 9-2320-365-20-2
2-1216
Change 1
e111.
M1079 110 VAC OUTLET J230 DOES NOT OPERATE (CONT)
5.
KNOWN INFO
TEST OPTIONS
Continuity Test or
STE/ICE-R Test
#91
REASON FOR QUESTION
POSSIBLE PROBLEMS
110 VAC outlets J231,
J232, J233, and J234 OK.
110 VAC outlet J235 does
not operate.
Faulty circuit breaker CB9.
Faulty wire 701C.
Faulty wire 702C.
Faulty relay K35.
Is continuity present across
circuit breaker CB9?
If continuity is not present,
circuit breaker CB9 is
faulty.
NO
Replace circuit breaker CB9
(para 16-64).
YES


Back to Top