TM 9-2320-365-34-2
8-16
Change 2
8-4.
TRANSFER CASE MODULE REPLACEMENT (CONT)
(4)
Position transfer case module (3) on transmission
adapter housing module (6).
(5)
Position 19 bolts (7) in transmission adapter
housing module (6).
(6)
Position bolt (8) in opposite side of transmission
adapter housing module (6).
(7)
Tighten 19 bolts (7) and bolt (8) to 42-50 lb-ft (57-
68 N•m).
(8)
Remove eight screws (9) and transfer case lift
bracket from transfer case module (3).
(9)
Install screen (10) in transfer case module (3).
(10) Install preformed packing (11) and 45-degree fitting
(12) on transfer case module (3).
(11) Install hose (13) on 45-degree fitting (12).
End of Task.
NOTE
•
Transmission should be in horizontal
position on maintenance stand.
•
Step (4) requires the aid of an assistant.