TM 9-2320-365-34-2
18-56
Change 2
18-5.
ENHANCED RESILIENT MOUNT INITIAL INSTALLATION (CONT)
(2)
Position mechanical stop (3) in vise.
(3) Remove self-locking nut (5), spring washer (6),
screw (7), and resilient mount (8).
Discard nut,
washer, screw, and mount.
b.
Mechanical Stop Resilient Mount Installation.
(1) Enlarge mounting hole on mechanical stop (1) to 0.6
in. (15 mm).
(2) Position enhanced resilient mount (2) on mechanical
stop (1) with bolt (3).
(3)
Tighten bolt (3) to 69-79 lb-ft (90-110 N•m).
NOTE
Perform step (3) on vehicles not equipped
with enhanced resilient mounts.