TM-9-2320-366-20-1

M1083 SERIES, 5 TON, 6x6, MEDIUM TACTICAL VEHICLES (MTV)

TECHNICAL MANUAL; MAINTENANCE INSTRUCTIONS; UNIT MAINTENANCE; VOLUME NO. 1 OF 5

FEBRUARY 2006
CHANGE 3

  TM-9-2320-366-20-1 - Page 981 of 1824

VOLTAGE TEST
CONTINUITY TEST
Change 1
2-604.49
TM 9-2320-366-20-1
(1)
Disconnect RH marker lamp connector from
connector P89.
(2)
Set multimeter to volts DC.
(3)
Connect positive (+) probe of multimeter to
connector P89.
(4)
Connect negative (-) probe of multimeter to
ground.
(5)
Position main light switch to SER DRIVE
(TM 9-2320-366-10-1) and note reading
on multimeter.
(6)
Position main light switch to OFF
(TM 9-2320-366-10-1).
(7)
If 12 VDC is not present, go to step 47
of this fault.
(1)
Remove two screws and lens cover from
RH marker light base.
(2)
Remove RH marker light lamp from socket.
(3)
Set multimeter to ohms.
(4)
Check continuity through RH marker light
lamp and note reading on multimeter.
(5)
If continuity is not present, replace RH
marker light lamp (para 7-38) and go to
step 6 of this fault if required.
(6)
Install RH marker light lamp in socket.
(7)
Install lens cover on RH marker light
base with two screws.
Inspect connector pins/sockets for damage,
corrosion, and serviceability.
Check that
connector pins are not pushed back and
are capable of making good contact.
NOTE
Use care when testing electrical connectors.
Do not damage connector pins or sockets
with multimeter probes.
Failure to comply
may result in damage to equipment.
CAUTION
Remove rings, bracelets, watches, necklaces,
and any other jewelry before working around
vehicle.
Jewelry can catch on equipment and
cause injury or short across electrical circuits
and cause severe burns or electrical shock.
WARNING


Back to Top