e104. M1084/M1086 MATERIAL HANDLING CRANE (MHC) DOES NOT OPERATE
KNOWN INFO
POSSIBLE PROBLEMS
TEST OPTIONS
Voltage Test or
STE/ICE-R Test #89
REASON FOR QUESTION
1.
Is input voltage present at
junction box terminal board
position 5?
WARNING
Read WARNING
on following page.
START
YES
NO
Go to step 2 of this fault.
Perform Electrical Troubleshooting (e115.
M1084/M1086 Material Handling Crane (MHC)
Overload Shutdown System Stays Activated).
2-1162
Change 2
TM 9-2320-366-20-2
Battery voltage OK.
Circuit breakers OK.
Auxiliary panel cable assembly
OK.
Dashboard wiring harness OK.
Hydraulic system OK.
Faulty crane power cable.
Faulty junction box internal
wiring.
Faulty reverse polarity diode(s).
INITIAL SETUP
Equipment Conditions
Engine shut down (TM 9-2320-366-10-1).
Personnel Required
(2)
Tools and Special Tools
Tool Kit, Genl Mech (Item 46, Appendix C)
Multimeter, Digital (Item 22, Appendix C)
STE/ICE-R (Item 41, Appendix C)
References
TM 9-4910-571-12&P
Crane will not operate if 24
VDC is not present at junction
box terminal board position 5.