Change 2
2-1167
(1)
Set multimeter to volts DC.
(2)
Connect positive (+) probe of multimeter on
connector P171-C.
(2)
Connect negative (-) probe of multimeter on
ground.
(3)
Position master power switch to on
(TM 9-2320-366-10-1) and note reading on
multimeter.
(4)
If 24 VDC is not present, repair wire 2069
(para 2-45) or replace crane power cable
(para 7-90).
(5)
Position master power switch to off
(TM 9-2320-366-10-1).
VOLTAGE TEST
TM 9-2320-366-20-2