TM 9-2320-366-20-2
TM 9-2320-366-20-2
TM 9-2320-366-20-2
TM 9-2320-366-20-2
TM 9-2320-366-20-2
2-1172
2-1172
2-1172
2-1172
2-1172
YES
KNOWN INFO
TEST OPTIONS
Continuity Test or
STE/ICE Test #91
REASON FOR QUESTION
If continuity is not present,
external remote control
cable is faulty.
Faulty external remote
control cable.
Faulty remote control box
ON/OFF switch.
Battery voltage OK.
Main power circuit breaker
switch OK.
Input connector OK.
Crane power cable OK.
Reverse polarity diodes
OK.
Control lockout relay OK.
Left outrigger proximity
sensing switch cable
assembly OK.
Right outrigger proximity
sensing switch cable
assembly OK.
Junction box internal
wiring OK.
Overload shutdown
system OK.
Hydraulic system
shutdown relay OK.
Remote control cable OK.
POSSIBLE PROBLEMS
2.
Is continuity present
from one end of external
remote control cable
pin E to other end of
external remote control
cable pin E?
NO
Replace external remote
control cable.
e105.
M1084/M1086 MATERIAL HANDLING CRANE (MHC) DOES NOT OPERATE FROM REMOTE CONTROL
e105.
M1084/M1086 MATERIAL HANDLING CRANE (MHC) DOES NOT OPERATE FROM REMOTE CONTROL
e105.
M1084/M1086 MATERIAL HANDLING CRANE (MHC) DOES NOT OPERATE FROM REMOTE CONTROL
e105.
M1084/M1086 MATERIAL HANDLING CRANE (MHC) DOES NOT OPERATE FROM REMOTE CONTROL
e105.
M1084/M1086 MATERIAL HANDLING CRANE (MHC) DOES NOT OPERATE FROM REMOTE CONTROL
(CONT)
(CONT)
(CONT)
(CONT)
(CONT)