NO
YES
KNOWN INFO
TEST OPTIONS
Continuity Test or
STE/ICE Test #91
REASON FOR QUESTION
Other crane functions from
remote station OK.
Hoist up solenoid cable OK.
Hoist up solenoid OK.
POSSIBLE PROBLEMS
Faulty hoist up/down
controller.
Faulty remote control
box internal wiring
harness.
Faulty external remote
control cable.
Faulty remote control
cable.
3.
This question eliminates
possible problems and
determines where to
continue troubleshooting.
Go to step 4 of this fault.
Go to step 5 of this fault.
Is continuity present
from remote control box
pin F to pin H?
e106.
M1084/M1086 MATERIAL HANDLING CRANE (MHC) HOIST UP DOES NOT OPERATE FROM REMOTE
e106.
M1084/M1086 MATERIAL HANDLING CRANE (MHC) HOIST UP DOES NOT OPERATE FROM REMOTE
e106.
M1084/M1086 MATERIAL HANDLING CRANE (MHC) HOIST UP DOES NOT OPERATE FROM REMOTE
e106.
M1084/M1086 MATERIAL HANDLING CRANE (MHC) HOIST UP DOES NOT OPERATE FROM REMOTE
e106.
M1084/M1086 MATERIAL HANDLING CRANE (MHC) HOIST UP DOES NOT OPERATE FROM REMOTE
STATION (CONT)
STATION (CONT)