CONTINUITY TEST
(1)
Set multimeter to ohms.
(2)
Connect positive (+) probe of multimeter on pin
F of remote control cable connector.
(3)
Connect negative (-) probe of multimeter on
terminal board lower position 23 and note
reading on multimeter.
(4)
If continuity is not present, replace remote
control cable (para 7-96).
(5)
If continuity is present, notify DS Maintenance.
(6)
Close cover on junction box.
(7)
Tighten four screws on junction box cover.
(8)
Stow crane (TM 9-2320-366-10-1).