NOTE
Step (5) requires the aid of
an assistant.
CONTINUITY TEST
(5)
Position HOIST UP/DOWN controller to DOWN
and note reading on multimeter.
(6)
If continuity is not present, go to step 4 of this
fault.
(7)
If continuity is present, go to step 5 of this fault.
(1)
Disconnect external remote control cable from
remote control box.
(2)
Set multimeter to ohms.
(3)
Connect positive (+) probe of multimeter on pin
G of connector on remote control box.
(4)
Connect negative (-) probe of multimeter on
pin H of connector on remote control box.