TM-9-2320-366-20-2

M1083 SERIES, 5 TON, 6x6, MEDIUM TACTICAL VEHICLES (MTV)

TECHNICAL MANUAL; MAINTENANCE INSTRUCTIONS; UNIT MAINTENANCE; VOLUME NO. 2 OF 5

FEBRUARY 2006
CHANGE 3

  TM-9-2320-366-20-2 - Page 288 of 1632

KNOWN INFO
POSSIBLE PROBLEMS
TEST OPTIONS
Continuity Test or
STE/ICE-R Test #91
REASON FOR QUESTION
2.
YES
NO
Replace crane power cable
(para 7-90).
2-1164
Change 2
TM 9-2320-366-20-2
e104. M1084/M1086 MATERIAL HANDLING CRANE (MHC) DOES NOT OPERATE (CONT)
Faulty crane power cable.
Faulty junction box internal
wiring.
Faulty reverse polarity diode(s).
Battery voltage OK.
Circuit breakers OK.
Auxiliary panel cable assembly
OK.
Dashboard wiring harness OK.
Hydraulic system OK.
Is continuity present
between crane power cable
connector pin B and
terminal board position 5?
If continuity is not present,
crane power cable is faulty.


Back to Top