TM 9-2320-366-20-3
TM 9-2320-366-20-3
TM 9-2320-366-20-3
TM 9-2320-366-20-3
TM 9-2320-366-20-3
2-2266
2-2266
2-2266
2-2266
2-2266
KNOWN INFO
1.
TEST OPTIONS
YES
NO
START
REASON FOR QUESTION
Hydraulic oil level OK.
Hydraulic lines
and fittings OK.
All functions operate
with PTO engaged.
POSSIBLE PROBLEMS
Hand Pump Test
Faulty input check valve.
Faulty hand pump.
Faulty check valve or hand
pump will prevent manual
operation of crane.
Does hand pump
build pressure?
WARNING
Read WARNING
on following page.
Notify DS Maintenance.
Notify DS Maintenance.
w10.
M1089 MATERIAL HANDLING CRANE (MHC) HAND PUMP DOES NOT WORK
INITIAL SETUP
Equipment Conditions
Engine shut down (TM 9-2320-366-10-1).
Tools and Special Tools
Tool Kit, Genl Mech (Item 46, Appendix C)
Pan, Drain (Item 24, Appendix C)
Goggles, Industrial (Item 15, Appendix C)
Materials/Parts
Rag, Wiping (Item 50, Appendix D)