TM-9-2320-366-20-3

M1083 SERIES, 5 TON, 6x6, MEDIUM TACTICAL VEHICLES (MTV)

TECHNICAL MANUAL; MAINTENANCE INSTRUCTIONS; UNIT MAINTENANCE; VOLUME NO. 3 OF 5

FEBRUARY 2006
CHANGE 3

  TM-9-2320-366-20-3 - Page 349 of 1396

NOTE
(1) Remove three screws and washers from
Power Distribution Panel (PDP).
(2) Remove three screws from Power Distribution
Panel (PDP).
(3) Lift Power Distribution Panel (PDP) to gain
access.
(4) Push in reset button on circuit breaker CB11
to see if it is tripped.
(5) If circuit breaker CB11 is not tripped, go to
step 3 of this fault.
(6) If circuit breaker CB11 trips agian, replace
circuit breaker CB11 (para 20-81).
Perform steps (7) through (9) if circuit
breaker CB11 is faulty.
(7) Position electrical distribution block cover on
power distribution shelf.
(8) Tighten wing screw on electrical distribution
block cover.
(9) Install wing screw in power distribution shelf.
TM 9-2320-366-20-3
Change 2
2-2275