x1. NO POWER TO DIGITIZATION RACK (CONT)
TEST OPTIONS
REASON FOR QUESTION
YES
NO
TEST OPTIONS
POSSIBLE PROBLEMS
Nothing.
2.
Visual Inspection
Go to step 3 of this fault.
TM 9-2320-366-20-3
Circuit breaker CB11 tripped.
Faulty circuit breaker CB11.
Faulty power cable from
terminal
lug TL24 to terminal lug TL20.
Faulty power cable from
terminal
lug TL23 to terminal lug TL16.
Is circuit breaker CB11
tripped?
Reset circuit breaker CB11.
If circuit breaker CB11, trips agian
replace circuit breaker CB11
(para 20-81).
If circuit breaker CB11 is
tripped, digitization rack will
not have power.