TM-9-2320-366-20-3

M1083 SERIES, 5 TON, 6x6, MEDIUM TACTICAL VEHICLES (MTV)

TECHNICAL MANUAL; MAINTENANCE INSTRUCTIONS; UNIT MAINTENANCE; VOLUME NO. 3 OF 5

FEBRUARY 2006
CHANGE 3

  TM-9-2320-366-20-3 - Page 346 of 1396

x1. NO POWER TO DIGITIZATION RACK
INITIAL SETUP
Equipment Conditions
Engine shut down (TM 9-2320-366-10-2)
Materials/Parts
Ties, Cable, Plastic (Item 69, Appendix D)
Tools/Special Tools
Multimeter, Digital (Item 22, Appendix C)
Tool Kit, Genl Mech (Item 46, Appendix C)
Personnel Required
(2)
TEST OPTIONS
POSSIBLE PROBLEMS
Nothing.
1.
WARNING
Read WARNING
on following page.
TEST OPTIONS
Voltage Test or
STE/ICE-R Test #89
REASON FOR QUESTION
This question eliminates
possible problems and
determines where
troubleshooting continues.
YES
NO
Go to step 2 of this fault.
Go to step 5 of this fault.
START
TM 9-2320-366-20-3
2-2272
Change 2
Is 24 VDC present at
terminal lug TL16?
Circuit breaker CB11 tripped.
Faulty circuit breaker CB11.
Faulty power cable from
terminal lug TL24 to terminal
lug TL20.
Faulty power cable from
terminal lug TL23 to terminal
lug TL16.
Faulty power cable from
terminal lug TL18 to terminal
block TB2.
Faulty Power Distribution
Panel (PD1).


Back to Top