TM 9-2320-366-20-4
7-131. 100 AMP REVERSE POLARITY RELAY TO POWER DISTRIBUTION (PDP) PANEL
24 VDC CABLE REPLACEMENT
This task covers:
a. Removal
b. Installation
c. Follow-On Maintenance
INITIAL SETUP
Equipment Conditions
Batteries disconnected (para 7-57).
PDP cover removed (para 16-2).
Spare tire lowered (TM 9-2320-366-10-2).
Lower radiator fan shroud removed (para 6-4).
Cab lowered (TM 9-2320-366-10-1).
Tools and Special Tools
Tool Kit, Genl Mech (Item 46, Appendix C)
Wrench, Torque, 0-200 lb-in. (Item 59, Appendix C)
Socket Set, Socket Wrench (Item 34, Appendix C)
Materials/Parts
Ties, Cable, Plastic (Item 69, Appendix D)
Nut, Self-Locking (2) (Item 153, Appendix G)
Lockwasher (Item 96, Appendix G)
Lockwasher (Item 84, Appendix G)
a. Removal.
(1) Remove three screws (1) and washers (2) from PDP (3).
(2) Remove three screws (4) from PDP (3).
(3) Lift PDP (3) outward to gain access.
NOTE
Remove plastic cable ties as required.
(4) Remove screw (5), lockwasher (6), terminal lug TL42 (7),
and four terminal lugs (8) from PDP (3).
Discard
lockwasher.
(5) Position four terminal lugs (8) on PDP (3) with screw (5).
7-637