7-131. 100 AMP REVERSE POLARITY RELAY TO POWER DISTRIBUTION (PDP) PANEL
24 VDC CABLE REPLACEMENT (CONT)
b. Installation.
NOTE
Install plastic cable ties as required.
(1) Position 100 amp reverse polarity relay to PDP 24 vdc
cable (1) through bottom of cab (2).
(2) Position 100 amp reverse polarity relay to PDP 24 vdc
cable (1) in clamp (3).
(3) Position clamps (3 and 4) on frame rail (5) with washer
(6), screw (7), washer (8), and self-locking nut (9).
(4) Tighten self-locking nut (9) to 97-120 lb-in. (11-14 N·m).
(5) Position 100 amp reverse polarity relay to PDP 24 vdc
cable (1) in clamp (10).
(6) Install clamp (10) on frame rail (5) with screw (11) and
self-locking nut (12).
(7) Tighten self-locking nut (12) to 97-120 lb-in. (11-14 N·m).