TM-9-2320-366-20-4

M1083 SERIES, 5 TON, 6x6, MEDIUM TACTICAL VEHICLES (MTV)

TECHNICAL MANUAL; MAINTENANCE INSTRUCTIONS; UNIT MAINTENANCE; VOLUME NO. 4 OF 5

FEBRUARY 2006
CHANGE 3

  TM-9-2320-366-20-4 - Page 299 of 1558

TM 9-2320-366-20-4
7-130. 100 AMP REVERSE POLARITY RELAY TO POWER DISTRIBUTION (PDP) PANEL
12 VDC CABLE REPLACEMENT
This task covers:
a. Removal
b. Installation
c. Follow-On Maintenance
INITIAL SETUP
Equipment Conditions
Batteries disconnected (para 7-57).
PDP cover removed (para 16-2).
Spare tire lowered (TM 9-2320-366-10-2).
Lower radiator fan shroud removed (para 6-4).
Tools and Special Tools
Tool Kit, Genl Mech (Item 46, Appendix C)
Wrench, Torque, 0-200 lb-in. (Item 59, Appendix C)
Socket Set, Socket Wrench (Item 34, Appendix C)
Materials/Parts
Ties, Cable, Plastic (Item 69, Appendix D)
Nut, Self-Locking (2) (Item 153, Appendix G)
Lockwasher (Item 96, Appendix G)
Lockwasher (Item 84, Appendix G)
a. Removal.
(1) Remove three screws (1) and washers (2) from PDP (3).
(2) Remove three screws (4) from PDP (3).
(3) Lift PDP (3) outward to gain access.
NOTE
Remove plastic cable ties as required.
(4) Remove screw (5), lockwasher (6), terminal lug
TL41 (7), and four terminal lugs (8) from PDP (3).
Discard lockwasher.
(5) Position four terminal lugs (8) on PDP (3) with
screw (5).
7-631


Back to Top