TM 9-2320-366-20-5
20-46. 200 AMP VOLTAGE REGULATOR REPLACEMENT
This task covers:
a. Removal
b. Installation
c. Follow-On Maintenance
INITIAL SETUP
Equipment Conditions
Cab raised (TM 9-2320-366-10-1).
Batteries disconnected (para 7-57).
Tools and Special Tools
Tool Kit, Genl Mech (Item 46, Appendix C)
Wrench, Torque, 0-200 lb-in. (Item 59, Appendix C)
Socket Set, Socket Wrench (Item 36, Appendix C)
Materials/Parts
Sealing Compound (Item 59, Appendix D)
Lockwasher (2) (Item 104, Appendix G)
Nut, Self-Locking (Item 143, Appendix G)
Nut, Self-Locking (Item 144, Appendix G)
a. Removal.
NOTE
Tag terminal lugs and connection points prior
to removal.
(1) Lift dust boot (1) on terminal lug TL110 (2).
(2) Remove self-locking nut (3), washer (4), and terminal lug
TL110 (2) from voltage regulator terminal (5). Discard
self-locking nut.
(3) Lift dust boot (6) on terminal lug TL35 (7).
(4) Remove self-locking nut (8), washer (9), and terminal lug
TL35 (7) from voltage regulator terminal (10). Discard
self-locking nut.
20-268