k1. DUMP BODY DOES NOT RAISE
TM 9-2320-366-34-1
Perform Electrical System Troubleshooting e143.
Dump Body Does Not Raise (TM 9-2320-366-20-2)
prior to beginning this task.
NOTE
TEST OPTIONS
KNOWN INFO
NO
REASON FOR QUESTION
Pressure Test or
STE/ICE-R Test #51
YES
Replace hydraulic rotary
pump (para 16-91).
1.
WARNING
CAUTION
Read WARNING and
CAUTION on
following pages.
2-1068
Change 2
Materials/Parts
Rag, Wiping (Item 60, Appendix C)
Tee, Tube (Item 88.3, Appendix C)
Tee, Tube (Item 88.2, Appendix C)
Reducer, Tube (Item 60.2, Appendix C)
Reducer, Tube (Item 60.1, Appendix C)
Hose Assembly, Nonmetallic (Item 40.1, Appendix C)
Cap, Tube (Item 17.3, Appendix C)
Plug, Tube Fitting, Threaded (Item 55.3, Appendix C)
Indicator, Temperature, Label (Item 40.4, Appendix C)
Personnel Required
(2)
References
TM 9-4910-571-12&P
INITIAL SETUP
Equipment Conditions
Engine shutdown (TM 9-2320-366-10-1)
Tools and Special Tools
Tool Kit, Genl Mech (Item 78, Appendix B)
Pan, Drain (Item 42, Appendix B)
Goggles, Industrial (item 28, Appendix B)
Lifting Bracket, Dump Body (Item 8, Appendix D)
Gloves, Mens (Item 34.2, Appendix C)
STE/ICE-R (Item 70, Appendix B)
Transmitter, Pressure (Item 1, Appendix G)
Hydraulic oil level OK.
PTO OK.
Hydraulic hoses and fittings
OK.
Hydraulic oil filter OK.
Dump body electrical system
OK.
POSSIBLE PROBLEMS
Faulty hydraulic rotary pump.
Faulty four-way relief valve.
Faulty pressure reducing
valve.
Faulty dump body hoist
cylinder.
If hydraulic rotary pump is not
supplying at least 2,850 PSI
(19,650 kPa), hydraulic rotary
is faulty.
Is hydraulic rotary pump
supplying at least 2,850 PSI
(19,650 kPa)?