TM 9-2320-366-34-4
18-108
Change 2
All data on pages 18-109 thru 18-131,
including page 18-109 through 18-132 deleted.
18-8.
ENHANCED RESILIENT MOUNT INITIAL INSTALLATION (CONT)
(7)
Apply sealing compound to threads of bolt (2).
(8)
Position spacer (8) and enhanced resilient mount (9)
on bolt (2).
(9)
Tighten resilient mount (9) 1 ½
turns after contact with
plate (4).
(10) Remove C-clamp from leaf spring (1).
e. Follow-On Maintenance.
(1)
Install gravel deflector (TM 9-2320-366-10).
(2)
Install front leaf spring (TM 9-2320-366-34).
(3)
Lower cab (TM 9-2320-366-10).
End of Task.
WARNING
Adhesives, solvents, and sealing compounds
can burn easily, can give off harmful vapors,
and are harmful to skin and clothing.
Keep
away from open fire and use in a well-
ventilated area.
If adhesive, solvent, or
sealing compound gets on skin or clothing,
wash immediately with soap and water.
Failure to comply may result in injury to
personnel.