TM 9-2320-387-24-l
I
KNOWN INFO
POWER AVAILABLE
TO
GAUGES
NO POWER AT WIPER
MOTOR
/
WIRING
REMOVE CLEVIS PINS AND TILT
1. STEXE-R
TEST 89
WINDSHIELD FORWARD. WITH
(Page 2-508)
ROTARY SWITCH IN THE RUN
2. MULTIMETER
POSITION, IS THERE BA-lTERY
VOLTAGE AT CONTACT P ON THE
BODY?
REASON
FOR QUESTION
These contacts provide power
and ground connections
to the
wiper motor.
INSTRUMENTS CIRCUIT
DIAGNOSTIC
FLOWCHART
-
TEST OPTIONS
POWER TO CONTACT
WIRING
!
%
M2
DO YOU HAVE CONTINUITY
FROM
CONTACT P ON THE WINDSHIELD
FRAME TO WIRE 27 AT THE
CONNECTOR?
TESl
1
r OPTIONS
1. STEIICE-R
TEST 91
(Page 2-508)
2. MULTIMETER
REASON
FOR QUESTION
These contacts provide power
and ground connections
to the
wiper motor.
2-356