TM-9-2320-387-24-1

TRUCK, UTILITY: S250 SHELTER CARRIER, 4X4, M1113

TECHNICAL MANUAL; UNIT, DIRECT SUPPORT AND GENERAL SUPPORT MAINTENANCE, VOLUME 1

DECEMBER 1997
CHANGE 1

  TM-9-2320-387-24-1 - Page 418 of 1205

TM
9-2320-387-24-l
INSTRUMENTS
CIRCUIT
DIAGNOSTIC
FLOWCHART
-
KNOWN INFO
WIRE 27C OK
WIRE 27D OK
CIRCUIT BREAKER
1 OK
WIRE 400D OK
SWITCHOK
POSSIBLE
PROBLEMS
WIRING
MOTOR
PCB
IS THERE CONTINUITY
FROM
WIRE 57E AT THE HEATER FAN
MOTOR-TO-BODY
GROUND?
1. STEXE-R
TEST 91
(Page 2-508)
2. MULTlMElER
REASON
FOR OUESTION
This wire provides the motor’s
connection to ground.
I
P5
I
I
IF THE PROBLEM CONTINUES,
REPLACE THE HEATER MOTOR.
RETURN TO THE INSTRUMENTS
TEST, PAGE 2-305.
2-364


Back to Top