TM 9-2320-440-13&P
0038-4
0038
MRP DOES NOT RETRACT (CONTINUED)
THAAD0633
NOTE
Rear suspension air spring pressure must be depleted to operate elevation cylinders. Air
spring pressure is depleted when AIR BAG PRESSURE DEPLETED indicator light is
steadily illuminated.
Step 3.
Check if AIR BAG PRESSURE DEPLETED indicator light is illuminated.
If AIR BAG PRESSURE DEPLETED indicator light is not illuminated or is
flashing, troubleshoot Air Bag Pressure Depleted Indicator Light(s) Do Not
Operate Properly (WP 0021).
THAAD0634
Step 4.
Turn engine start switch OFF (
Inspect hydraulic hoses 2742, 2743,
2760, 2761, and 2781, tubing, and fittings from MRP distribution manifold and control
valves to left and right elevation cylinders and hydraulic reservoir for leaks, kinks, and
damage (see WP 0119).
If hydraulic hoses, tubes and/or fittings leak, or are damaged, tighten loose
fittings or replace damaged hoses and/or tubes (WP 0119).
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
TM 9-2320-347-10)