TM-9-2320-440-13-P

TERMINAL HIGH ALTITUDE AREA DEFENSE (THAAD) CARRIER

TECHNICAL MANUAL; OPERATOR’S AND FIELD LEVEL MAINTENANCE MANUAL (INCLUDING REPAIR PARTS AND SPECIAL TOOLS LIST)

AUGUST 2010

  TM-9-2320-440-13-P - Page 369 of 1616

TM 9-2320-440-13&P
0038-11
0038
MRP DOES NOT RETRACT (CONTINUED)
THAAD0626A
WARNING
Remove rings, wristwatches, neck chains, and any other jewelry before working
around vehicle.
Jewelry can catch on equipment and cause serious injury.
Jewelry
and tools may short across electrical circuits and cause damage to equipment or
severe burns or electrical shock to personnel.
NOTE
Perform Step 13 if no vdc is present on wire 1972A at connector REC13, terminal 2 in
Step 11.
Perform Step 14 if no vdc is present on wire 1972B at connector REC13, terminal 3 in
Step 11.
Step 13.
Disconnect THAAD control valve harness VIM No. 1, 40 pin connector (WP 0089).
Check for continuity across wire 1972A from VIM No. 1, 40 pin connector, terminal 6 to
connector REC13, terminal 6.
a.
If there is continuity, replace VIM No. 1 (WP 0089).
b.
If there is no continuity, repair wire 1972A (TM 9-2320-325-14&P) or
replace THAAD control valve harness (WP 0088).
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION


Back to Top