TM-9-2320-440-13-P

TERMINAL HIGH ALTITUDE AREA DEFENSE (THAAD) CARRIER

TECHNICAL MANUAL; OPERATOR’S AND FIELD LEVEL MAINTENANCE MANUAL (INCLUDING REPAIR PARTS AND SPECIAL TOOLS LIST)

AUGUST 2010

  TM-9-2320-440-13-P - Page 376 of 1616

TM 9-2320-440-13&P
0038-18
0038
MRP DOES NOT RETRACT (CONTINUED)
THAAD0639A
WARNING
Remove rings, wristwatches, neck chains, and any other jewelry before working
around vehicle.
Jewelry can catch on equipment and cause serious injury.
Jewelry
and tools may short across electrical circuits and cause damage to equipment or
severe burns or electrical shock to personnel.
Step 21.
Disconnect THAAD chassis harness input module black connector.
Check for
continuity across each wire as indicated in the following table:
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
If continuity is not measured on any one wire, notify Supervisor.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
Wire Number
Connector/Terminal
Connector/Terminal
1904
Black Connector/P2
MUJB Connector/O
1910
Black Connector/P8
MUJB Connector/M
1435
Black Connector/P9
Vehicle Ground
1435
Black Connector/P12
Vehicle Ground
1435
Black Connector/P9
Black Connector/P12


Back to Top